Removing and installing disk modules

Use the following instructions to replace a faulty disk module. It should be replaced
while the array is running (hot-swapped).

NOTE: Grass Valley does not support mixing disk drives of differing capacities
within a RAID chassis connected to a Profile XP Media Platform or Open SAN. All
disk drives in any RAID chassis must be of the same capacity. For example, if a
PFR600 and a PFR600E are used, all the disk drives in both the PFR600 and the
PFR600E must be of the same capacity.

Moving disk modules

CAUTION: You can destroy the media file system beyond recovery if you move a
disk module to a different slot. The service person can move a disk module when you
don’t care about losing the media in the media file system and under the following
cautions:

• The disk module must be unbound.

• Moving a drive module that is part of a LUN to another slot makes all information

on the LUN inaccessible.

• You must remove and install the disk module while the storage system is powered

up.

A disk module must be inserted all the way or removed entirely. Do not leave a disk
module partially removed except for periods when you are allowing it to spin down.
When replacing multiple disks, observe the following:

• After removing a disk module, wait for the activity LEDs on the other disk modules

to resume a steady flicker before removing the next module.

• After inserting a disk module, wait for the activity LEDs on the other drives to

resume a steady flicker before inserting the next module.

CAUTION: Handle a disk module gently and use an ESD wristband. Do not remove
a faulty disk module until you have a replacement module (with the same part
number) or a filler module available.

!

!