GUIDE TO INSTALLATION AND OPERATION

22 | SME-1901 / 1911

The panel is organized in columns.

Status/Name
This contains an expandable tree listing all the
alarms reported by this SME-1901/1911 card.

• Each alarm name includes an icon that

shows its current status

• Some alarms may be text-only and the

alarm status is shown in the name and not
by a status icon


The Card LED, Overall alarm and GSM
contribution
columns contain pulldown lists that
allow the level of contribution of each individual
alarm to the alarm named in the column heading
to be set.

 Click on the alarm icon to

see the available levels;
then click on one to select it



Card LED
This column allows configuration of the
contribution of selected individual alarms to the
status LED located on the front card edge. The
Card LED status is shown at the bottom of the
alarm tree in the Status/Name column.

Overall Alarm
This column allows configuration of the
contribution of each individual alarm to the Overall
Alarm associated with this card. The Overall
Alarm is shown in the upper left corner of the
iControl panel, and also appears at the bottom of
the Status/Name column.

GSM Contribution
This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status associated with
this card. GSM is a dynamic register of all iControl system alarms, and is also an alarm provider for external
applications. The possible values for this contribution are related to the Overall alarm contribution:

• If the Overall alarm contribution is selected as Disabled, the GSM alarm contribution can be set to any available

value

• If the Overall alarm contribution is selected as any level other than disabled, the GSM contribution is forced to

follow the Overall Alarm.

Figure 5-16 Alarm Configuration panel