HEIDENHAIN TNC 320 (340 55x-04) Cycle programming User Manual

Page 375

Advertising
background image

HEIDENHAIN TNC 320

375

16.4 MEA

S

URE ANGLE (Cy

c

le 420, DIN/ISO: G420)

U

Traverse direction 1

Q267: Direction in which the

probe is to approach the workpiece:
-1: Negative traverse direction
+1: Positive traverse direction

U

Measuring height in the touch probe axis

Q261 (absolute): Coordinate of the ball tip
center (= touch point) in the touch probe axis in
which the measurement is to be made. Input
range –99999.9999 to 99999.9999

U

Setup clearance

Q320 (incremental): Additional

distance between measuring point and ball tip.
Q320 is added to SET_UP (touch probe table). Input
range 0 to 99999.9999

U

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
–99999.9999 to 99999.9999

U

Traversing to clearance height

Q301: Definition of

how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points

U

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:
0: No measuring log
1: Generate measuring log: the TNC saves the log file
TCHPR420.TXT
by default in the directory TNC:\
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.

Example: NC blocks

5 TCH PROBE 420 MEASURE ANGLE

Q263=+10

;1ST POINT 1ST AXIS

Q264=+10

;1ST POINT 2ND AXIS

Q265=+15

;2ND POINT 1ST AXIS

Q266=+95

;2ND POINT 2ND AXIS

Q272=1

;MEASURING AXIS

Q267=-1

;TRAVERSE DIRECTION

Q261=-5

;MEASURING HEIGHT

Q320=0

;SETUP CLEARANCE

Q260=+10

;CLEARANCE HEIGHT

Q301=1

;MOVE TO CLEARANCE

Q281=1

;MEASURING LOG