8 set the dat um with a 3-d t o uc h pr obe – HEIDENHAIN TNC 320 (340 55x-05) User Manual

Page 396

Advertising
background image

396

Manual Operation and Setup

12.8 Set the dat

um with a 3-D t

o

uc

h pr

obe

Measuring workpiece dimensions

U

Select the probe function by pressing the PROBING

POS soft key

U

Position the touch probe at a position near the first

touch point A

U

Select the probing direction by soft key

U

To probe the workpiece, press the machine START

button

U

If you will need the current datum later, write down

the value that appears in the Datum display

U

Datum: Enter "0"

U

To terminate the dialog, press the END key

U

Select the probe function by pressing the PROBING

POS soft key

U

Position the touch probe at a position near the second

touch point B

U

Select the probe direction with the soft keys: Same

axis but from the opposite direction

U

To probe the workpiece, press the machine START

button

The value displayed as datum is the distance between the two points
on the coordinate axis.

To return to the datum that was active before the length
measurement:

U

Select the probe function by pressing the PROBING POS soft key

U

Probe the first touch point again.

U

Set the datum to the value that you wrote down previously.

U

To terminate the dialog, press the END key

Measuring angles

You can use the 3-D touch probe to measure angles in the working
plane. You can measure

„

the angle between the angle reference axis and a workpiece edge,
or

„

the angle between two sides

The measured angle is displayed as a value of maximum 90°.

Y

X

Z

A

B

l