1 gener a l user p a ra met e rs – HEIDENHAIN iTNC 530 (340 49x-03) ISO programming User Manual

Page 629

Advertising
background image

HEIDENHAIN iTNC 530

629

14.1 Gener

a

l User P

a

ra

met

e

rs

External data transfer

Integrating TNC interfaces EXT1 (5020.0)
and EXT2 (5020.1) to an external device

MP5020.x
7 data bits (ASCII code, 8th bit = parity): +0
8 data bits (ASCII code, 9th bit = parity): +1

Block Check Character (BCC) any: +0
Block Check Character (BCC) control character not permitted: +2

Transmission stop through RTS active: +4
Transmission stop through RTS inactive: +0

Transmission stop through DC3 active: +8
Transmission stop through DC3 inactive: +0

Character parity even: +0
Character parity odd: +16

Character parity not desired: +0
Character parity desired: +32

Number of stop bits that are transmitted at the end of a character:
1 stop bit: +0
2 stop bits: +64
1 stop bit: +128
1 stop bit: +192

Example:

Use the following setting to adjust the TNC interface EXT2 (MP 5020.1) to
an external non-HEIDENHAIN device:

8 data bits, any BCC, transmission stop through DC3, even character
parity, character parity desired, 2 stop bits

Input for MP 5020.1: 1+0+8+0+32+64 = 105

Interface type for EXT1 (5030.0) and
EXT2 (5030.1)

MP5030.x
Standard transmission: 0
Interface for blockwise transfer: 1

3-D Touch Probes

Select signal transmission

MP6010
Touch probe with cable transmission: 0
Touch probe with infrared transmission: 1

Probing feed rate for triggering touch
probes

MP6120
1
to 3 000 [mm/min]

Maximum traverse to first probe point

MP6130
0.001
to 99 999.9999 [mm]

Safety clearance to probing point during
automatic measurement

MP6140
0.001
to 99 999.9999 [mm]

Rapid traverse for triggering touch probes

MP6150
1
to 300 000 [mm/min]