1 gener a l user p a ra met e rs – HEIDENHAIN iTNC 530 (340 49x-03) ISO programming User Manual

Page 630

Advertising
background image

630

14 Tables and Overviews

14.1 Gener

a

l User P

a

ra

met

e

rs

Pre-position at rapid traverse

MP6151
Pre-position with speed from MP6150: 0
Pre-position at rapid traverse: 1

Measure center misalignment of the stylus
when calibrating a triggering touch probe

MP6160
No 180° rotation of the 3-D touch probe during calibration: 0
M function for 180° rotation of the touch probe during calibration: 1 to 999

M function for orienting the infrared sensor
before each measuring cycle

MP6161
Function inactive: 0
Orientation directly through the NC: -1
M function for orienting the touch probe: 1 to 999

Angle of orientation for the infrared sensor

MP6162
0
to 359.9999 [°]

Difference between the current angle of
orientation and the angle of orientation set
in MP 6162; when the entered difference is
reached, an oriented spindle stop is to be
carried out.

MP6163
0
to 3.0000 [°]

Automatic operation: Automatically orient
the infrared sensor before probing to the
programmed probing direction

MP6165
Function inactive: 0
Orient infrared sensor: 1

Manual operation: Compensate the probe
direction taking an active basic rotation into
account

MP6166
Function inactive: 0
Take basic rotation into account: 1

Multiple measurement for programmable
probe function

MP6170
1
to 3

Confidence range for multiple
measurement

MP6171
0.001
to 0.999 [mm]

Automatic calibration cycle: Center of the
calibration ring in the X axis referenced to
the machine datum

MP6180.0 (traverse range 1) to MP6180.2 (traverse range3)
0
to 99 999.9999 [mm]

Automatic calibration cycle: Center of the
calibration ring in the Y axis referenced to
the machine datum

MP6181.x (traverse range 1) to MP6181.2 (traverse range3)
0
to 99 999.9999 [mm]

Automatic calibration cycle: Upper edge of
the calibration ring in the Z axis referenced
to the machine datum

MP6182.x (traverse range 1) to MP6182.2 (traverse range3)
0
to 99 999.9999 [mm]

Automatic calibration cycle: Distance below
the upper edge of the ring where the
calibration is carried out by the TNC

MP6185.x (traverse range 1) to MP6185.2 (traverse range 3)
0.1
to 99 999.9999 [mm]

Radius measurement with the TT 130 touch
probe: Probing direction

MP6505.0 (traverse range 1) to 6505.2 (traverse range 3)
Positive probing direction in the angle reference axis (0° axis): 0
Positive probing direction in the +90° axis: 1
Negative probing direction in the angle reference axis (0° axis): 2
Negative probing direction in the +90° axis: 3

3-D Touch Probes