New functions of software 340 49x-02, New functions of software 340 49x-03, Tnc model, sof tw a re and f eat ur es – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual

Page 8

Advertising
background image

8

TNC Model, Sof

tw

a

re

and F

eat

ur

es

New functions of software 340 49x-02

„

New machine parameter for defining the positioning speed (see
“Touch trigger probe, rapid traverse for positioning: MP6151” on
page 25)

„

New machine parameter for consideration of basic rotation in
Manual Operation (see “Consider a basic rotation in the Manual
Operation mode: MP6166” on page 24)

„

Cycles 420 to 431 for automatic tool measurement were improved
so that the measuring log can now also be displayed on the screen
(see “Recording the results of measurement” on page 109)

„

A new cycle that enables you to set global touch probe parameters
was introduced (see “FAST PROBING (touch probe cycle 441, DIN/
ISO: G441, FCL 2 function)” on page 156)

New functions of software 340 49x-03

„

New cycle for setting a datum in the center of a slot (see “SLOT
CENTER REFERENCE POINT (touch probe cycle 408, DIN/ISO:
G408, FCL 3 function)” on page 70)

„

New cycle for setting a datum in the center of a ridge (see “SLOT
CENTER REFERENCE POINT (touch probe cycle 409, DIN/ISO:
G409, FCL 3 function)” on page 73)

„

New 3-D probing cycle (see “MEASURING IN 3-D (touch probe
cycle 4, FCL 3 function)” on page 152)

„

Cycle 401 now also allows you to compensate workpiece
misalignment by rotating the rotary table (see “BASIC ROTATION
from two holes (touch probe cycle 401, DIN/ISO: G401)” on page
52)

„

Cycle 402 now also allows you to compensate workpiece
misalignment by rotating the rotary table (see “BASIC ROTATION
over two studs (touch probe cycle 402, DIN/ISO: G402)” on page 55)

„

In the cycles for datum setting, the results of measurement are
available in the Q parameters Q15X (see “Measurement results in Q
parameters” on page 69)

Advertising