2 pr eset ting aut o matically – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual

Page 85

Advertising
background image

HEIDENHAIN iTNC 530

85

3.2 Pr

eset

ting aut

o

matically

DATUM FROM OUTSIDE OF CIRCLE
(touch probe cycle 413, DIN/ISO: G413)

Touch probe cycle 413 finds the center of a circular stud and defines
it as datum. If desired, the TNC can also enter the coordinates into a
datum table or the preset table.

1

The TNC positions the touch probe to the starting points at rapid
traverse (value from MP6150 or MP6361) following the positioning
logic (see “Running touch probe cycles” on page 26) to the
starting point

1

. The TNC calculates the probe starting points from

the data in the cycle and the safety clearance from MP6140.

2

Then the touch probe moves to the entered measuring height and
probes the first touch point at the probing feed rate (MP6120 or
MP6360). The TNC derives the probing direction automatically
from the programmed starting angle.

3

Then the touch probe moves in a circular arc either at measuring
height or at clearance height to the next starting point

2

and probes

the second touch point.

4

The TNC positions the probe to starting point

3

and then to starting

point

4

to probe the third and fourth touch points.

5

Finally the TNC returns the touch probe to the clearance height and
processes the determined datum depending on the cycle
parameters Q303 and Q305 (see “Saving the calculated datum”
on page 69)
and saves the actual values in the Q parameters listed
below

6

If desired, the TNC subsequently measures the datum in the touch
probe axis in a separate probing.

X

Y

1

2

4

3

Parameter number

Meaning

Q151

Actual value of center in reference axis

Q152

Actual value of center in minor axis

Q153

Actual value of diameter

Before programming, note the following

To prevent a collision between the touch probe and the
workpiece, enter a high estimate for the nominal diameter
of the pocket (or hole).

Before a cycle definition you must have programmed a
tool call to define the touch probe axis.

Advertising