Using touch probe cycles

13.1

Gener

al

inf

or

m

ation

about

to

uc

h

pr

obe

cy

cles

Defining the touch probe cycle in the Programming and Editing

mode of operation

The soft-key row shows all available touch probe

functions divided into groups.

Select the desired probe cycle group, for example

datum setting. Cycles for automatic tool

measurement are available only if your machine has

been prepared for them.

Select a cycle, e.g. datum setting at pocket center.

The TNC initiates the programming dialog and asks

for all required input values. At the same time a

graphic of the input parameters is displayed in the

right screen window. The parameter that is asked for

in the dialog prompt is highlighted.

Enter all parameters requested by the TNC and

conclude each entry with the ENT key.

The TNC ends the dialog when all required data has

been entered

Example: NC blocks

5 TCH PROBE 410 DATUM INSIDE RECTAN.

Q321=+50

;CENTER IN 1ST AXIS

Q322=+50

;CENTER IN 2ND AXIS

Q323=60

;1ST SIDE LENGTH

Q324=20

;2ND SIDE LENGTH

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q305=10

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+0

;DATUM

Group of measuring cycles

Soft key

Page

Cycles for automatic measurement and

compensation of workpiece

misalignment

Page 334

Cycles for automatic workpiece

presetting

Page 356

Cycles for automatic workpiece

inspection

Page 410

Calibration cycles, special cycles

Page 460

Cycles for automatic kinematics

measurement

Page 476

Cycles for automatic tool measurement

(enabled by the machine tool builder)

Page 508

Advertising