Manual operation and setup
14.4 Functional safety FS (option)
14
418
TNC 620 | User's Manual for DIN/ISO Programming | 3/2014
Additional status displays
On a control with functional safety FS, the general status display
contains additional information about the current status of safety
functions. The TNC shows this information as operating statuses of
the status displays
T, S and F
Status display
Brief description
STO
Energy supply to the spindle or a feed
drive is interrupted.
SLS
Safely-limited speed: A safely limited
speed is active.
SOS
Safe operating stop: Safe operating stop is
active.
STO
Safe torque off: Energy supply to the
motor is interrupted.
The TNC shows the active safety-related mode of operation with an
icon in the header to the right of the operating mode text:
Button
Safety-related operating mode
SOM_1 operating mode active
SOM_2 mode active
SOM_3 mode active
SOM_4 mode active