Datum setting without a 3-d touch probe 15.5 – HEIDENHAIN TNC 640 (34059x-02) User Manual

Page 513

Advertising
background image

Datum setting without a 3-D touch probe 15.5

15

TNC 640 | User's Manual
HEIDENHAIN Conversational Programming | 5/2013

513

Activating a datum from the preset table in the Manual
Operation mode

When activating a datum from the preset table, the
TNC resets the active datum shift, mirroring, rotation
and scaling factor.

However, a coordinate transformation that was
programmed in Cycle 19 Tilted Working Plane, or
through the PLANE function, remains active.

Select the

MANUAL OPERATION mode

Display the preset table

Select the datum number you want to activate, or

With the GOTO key, select the datum number that
you want to activate. Confirm with the ENT key

Activate the datum

Confirm activation of the datum. The TNC sets the
display and—if defined—the basic rotation

Exit the preset table

Activating a datum from the preset table in an NC program

To activate datums from the preset table during program run, use
Cycle 247. In Cycle 247 you define the number of the datum that
you want to activate (see User's Manual, Cycles, Cycle 247 SET
DATUM).

Advertising