DVI DA2 and DVI DA4 • Installation and Operation

2-3

5

.

Reliable earthing (grounding) —

Maintain reliable

grounding of rack-mounted equipment. Pay particular

attention to supply connections other than direct

connections to the branch circuit (such as the use of power

strips).

Rack mounting procedure

These distribution amplifiers can be mounted on any of the

following rack shelves:

RSF 123 (part # 60-190-20) 1U 3.5" VersaTools

® rack shelf kit

RSB 123 (part # 60-604-21) 1U 3.5" VersaTools basic rack shelf

RSU 126 (part # 60-190-10) 1U 6" rack shelf kit

RSB 126 (part # 60-604-11) 1U 6" basic rack shelf

RSU 129 (part # 60-190-01) 1U 9.5" rack shelf kit

RSB 129 (part # 60-604-02) 1U 9.5" basic rack shelf

Use 2 mounting holes on
opposite corners.

(2) 4-40 x 3/16"
Screws

1U Universal Rack Shelf

Front false
faceplate
uses 2
screws.

1/2 Rack Width Front False
Faceplate

Rack mounting the DVI DA2 or DVI DA4

To mount the distribution amplifier on a rack shelf:
1

.

If necessary, remove rubber feet from the bottom of the

unit.

2

.

Align two diagonally opposite mounting holes on the

unit with two pre-drilled holes in the shelf. Use the two

provided 4-40 x 3/16" screws to secure the unit on the

shelf.

3

.

Install other unit(s) or false faceplate(s) on the rack shelf.