Initial installation – Enviro Cara DR C-11500 User Manual

Page 15

Advertising
background image

Initial Installation

QUALIFIED INSTALLERS ONLY

P

lanning

Y

our

i

nstallation

:

The Cara DR is only for horizontal rear vent installations. The maximum horizontal is 2’ (61 cm) and the

slope on the vent must be 1¼” per foot (3.2 cm per 30 cm). No vent restrictor is required and no elbows

are allowed. When planning your installation, it will be necessary to select the proper length of vent pipe

for your particular requirements. It is important to note when passing through a wall, the maximum

allowable wall thickness is 10 inches (25.4 cm); 1½ inches (3.8 cm) clearance to combustibles must be

maintained. To connect the venting system to the appliance flue outlet, a twist-lock adapter is built into

the appliance at the factory.
Note: If necessary to get above grade the Cara DR can be installed using a 14” or 36” snorkel.

a

PProved

v

ent

P

arts

:

Table 5: Approved Vent Manufacturers.

Manufacturer

Trade Name

Nominal Sizes

American Metal Products

AmeriVent Direct

4” - 6 5/8”

Security Chimneys International LTD

Secure Vent

4” - 6 5/8”

Selkirk Metalbestos

Direct-Temp

4” - 6 5/8”

Simpson Dura-Vent

Direct Vent GS

4” - 6 5/8”

Table 6: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS).

Direct Vent GS

Direct-Temp

Secure Vent

Ameri Vent Direct Description

908

4DT-6

SV4L6

6” pipe length

4D7

7” pipe length

907

4DT-9

9” pipe length

906

4DT-12

SV4L12

4D12

12” pipe length

904

4DT-24

SV4L24

4D2

24” pipe length

942

4DT-WT

SV4RSN

4DWT

Wall thimble

970

4DT-HKA

SV0SHK

4DHTK1

Horizontal termination kit (SD: Basic Kit,

SEL: Kit A, SC: Standard Kit)

984

4DT-HC

SV4CHC

4DHC

Horizontal square termination

The Cara DR fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS

“AMERIVENT DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SECURITY CHIMNEY’S

“SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for

horizontal venting. When using Simpson Duravent, it is recommended that, before installation, a bead

of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner

joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the

particular requirements.
WARNING: Do not mix parts from different vent manufacturers’ systems. EXCEPTION TO WARNING:

This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction

with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the

Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the

appliance.

15

Advertising
This manual is related to the following products: