Subject: Technical Note

Product: NS300/NS500

Doc#: eng.MCD.05.106

Title: NS300/500 Master Ladder Example


May 9, 2007

Page 15

of 16

Working registers and selecting the proper data to place in output bytes 2-3

Loading the proper data into output bytes 2-3 requires the use of an accumulator. For motion commands, output

bytes 2-3 are bit settings, but for set/read commands, output bytes 2-3 combine to become a word type register.

If the command is a set/read command and, more specifically, a parameter read or parameter write command,

the parameter value from MW00014 is loaded to the accumulator once the MOD_R response bit from the

NS300/500 is acknowledged. If the command is any other set/read command, the accumulator is loaded with

zero. Motion command bits are set in a working register, DW00016, and then loaded to the accumulator for

motion commands.

Line 48

Line 47

Line 46

Motion command bits set in

NS_Bytes_2_3_Working

DW00016

Parameter number for Set/

Read commands loaded to

MW00014

Accumulator

loaded with zero

Set/Read

command?

Accumulator loaded with
NS_Bytes_2_3_Working

Parameter

Read/Write?

No change to

accumulator

(still zero)

Accumulator

loaded with

parameter number

Accumulator loaded into

NS300_BytesOut_2_3

No

Yes

No

Yes

MOD_R

active?

Fig 12. Output Bytes 2-3 Data Selection Process