background image

Subject: Technical Note

Product: NS300/NS500

Doc#: EM.MCD.05.106

Title: NS300/500 Master Ladder Example


Doc#: Copyright Yaskawa Electric America

©2004

May 9, 2007

Page 9

of 16

The last recommended programming practice is to force off any non-utilized command bits. Two bits are provided

in order to modify the motion command by indicating a direction, using the DIR bit, or indicating that the move

should be absolute or incremental, using the INC bit. These bits are only valid for selected commands, and

otherwise have no significance. When a command is selected that renders these specific bits inactive, they

should be set off. This is shown below in line 41, which controls the DIR bit.

Fig 4. DIR Bit Circuit

The PLC_DIR bit commands the DIR coil. However, the DIR coil is only valid during feed, step, station, or point

table commands. If the PLC_DIR is set, but the current command is not of the commands that can utilize the DIR

command, then this bit is left off and properly follows the recommended practice.