Clearances locating fireplace – Empire Comfort Systems DVX36DP31 User Manual

Page 8

Advertising
background image

25613-0-0309

Page 8

Mantel Chart (Figure 3)

Figure 3

Clearances (Figure 4)

Clearance from top front edge of fireplace to ceiling is 36"

Clearance from side of fireplace to adjacent sidewall is 6".

36”

(914mm)

6” (152mm)

Figure 4

Figure 5

Note: Island (C) and Room Divider (F)

installation is possible as long as the

horizontal portion of the vent system

(H) does not exceed 20 feet with a

minimum vertical run of 8 feet. See

details in Venting Section.
When you install your Direct Vent

Fireplace in (F) Room divider or (A) Flat

on wall corner positions, a minimum of

6 inches clearance must be maintained

from the perpendicular wall and the

front edge of the appliance.

Figure 2

Combustible Material

No greeting cards, stockings or ornamentation of any type should

be placed on or attached to the fireplace. The flow of heat can

ignite combustibles.

(A) CORNER

INSTALLATION

(E) ANGLED CORNER

INSTALLATION

(C) ISLAND

INSTALLATION

(B) CABINET

INSTALLATION

(F) ROOM DIVIDER

INSTALLATION

(D) FLUSH WALL

INSTALLATION

Clearance to Combustibles

Back

0" (0 mm)

Side

0" (0 mm)

Floor

0" (0 mm)

Top Stand-off

0" (0 mm)

Top Framing Edge

6" (152 mm)

GLASS FRONT

6”

SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH

2” x 4” HEADER

STAND OFF
6” (152mm) HEIGHT
ABOVE TOP OF
FIREPLACE

NAILING
FLANGES

TOP FRAMING
LEDGE

NON-COMBUSTIBLE
FIRST 6” (SEE
MAGNIFIED VIEW)

FINISHED WALL
(COMBUSTIBLE)

SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT

CLEARANCES

LOCATING FIREPLACE

MANTEL

19”

18 3/4”

17”

16”

15”

14”

13”

12”

11”

10”

2 1/4”

1 1/2”

3/4”

8”

6”

4 1/2”

3 3/4”

3”

12” (305mm)

10” (254mm)

TOP EDGE OF FIREPLACE

COMBUSTIBLE TRIM AND
MANTELS ALLOWED IN
SHADED AREA