25 torque compensation, Torque compensation -35 – Yaskawa J7 Drive User Manual

Page 70

Advertising
background image

5-35

n63 :

Torque Compensation Gain (K

T

)

Factory setting:

1.0

Range: 0.0 to 2.5

Torque Compensation Gain (

n63

) adjusts how

much the output voltage is boosted when motor
load increases. It is used to compensate for
resistive losses in the motor and the wiring
between the drive and the motor. Torque
compensation is only active when the Drive is in
the V/f control mode.

OUTPUT FREQUENCY

( HZ )

OUTPUT VOLTAGE

( VAC )

460

345

230

115

14 V

0

0

1.5 HZ

30

60

PROGRAMMED V/F PATTERN

(NO LOAD)

AUTO TORQUE BOOST

V/F PATTERN

Example of Torque Compensation

Operation

5.25 TORQUE COMPENSATION