Multi-function outputs: h2 – Yaskawa G5HHP Drive User Manual

Page 294

Advertising
background image

User Constants

8.2.6 Terminal Constants: H

8 - 28

Setting

value

Page

Control Methods

Function

Setting

value

Page

Flux

vector

Open

loop

Vector

V/f

w/

PG

V/f

Function

64

External speed search command 3

f

f

f

f

--

65

KEB (deceleration at momentary power loss) command (NO contact)

f

f

f

f

--

66

KEB (deceleration at momentary power loss) command (NO contact)

f

f

f

f

--

71

Speed/torque control change (ON: Torque control)

x

x

x

f

7 - 74

72

Zero-servo command (ON: Zero-servo)

x

x

x

f

7 - 75

77

Speed control (ASR) proportional gain switch (ON: C5-03)

x

x

x

f

7 - 75

J

Multi-function Outputs: H2

C

t t

S tti

F t

Change

Control Methods

Constant

Number

Name

Display

Setting

Range

Factory

Setting

Change

during

Opera-

tion

V/f

V/f

with

PG

Open

Loop

Vector

Flux

Vector

Page

H2-01

Multi-function input

(terminal 53-57)

Terminal 53 Sel

0 to 37

0

x

B

B

B

B

7 - 77

H2-02

Multi-function input

(terminal 19)

Terminal 19 Sel

0 to 37

1

x

B

B

B

B

7 - 77

H2-03

Multi-function input

(terminal 20)

Terminal 20 Sel

0 to 37

2

x

B

B

B

B

7 - 77

Multi-function Output Functions

Control Methods

Setting

value

Function

V/f

V/f

w/

PG

Open

loop

Vec-

tor

Flux
vec-

tor

Page

0

During run ON: run command is ON or voltage is being output)

f

f

f

f

7 - 78

1

Zero-speed

f

f

f

f

7 - 78

2

Frequency agree 1: (Detection width L4-02)

f

f

f

f

7 - 92

3

Desired frequency agree 1 (ON: Output frequency = ±L4-01, detection width in L4-02)

f

f

f

f

7 - 92

4

Frequency (Four) detection 1 (ON: +L4-01≧output frequency≧--L4-01, detection width in L4-02)

f

f

f

f

7 - 92

5

Frequency (Four) detection 2
(ON: Output frequency≧+L4-01 or output frequency≦--L4-01, detection width in L4-02)

f

f

f

f

7 - 92

6

Inverter operation ready

READY: After initialization, no faults

f

f

f

f

--

7

During DC bus undervoltage (UV) detection

f

f

f

f

--

8

During baseblock (ON: during baseblock)

f

f

f

f

--

9

Frequency reference selection (ON: Frequency reference from Operator)

f

f

f

f

--

A

Run command selection (ON: Run command from Operator)

f

f

f

f

--

B

Overtorque detection 1 NO (NO contact: Overtorque detection at ON)

f

f

f

f

7 - 95

C

Loss of frequency reference (Effective when operation selection is “1” for L4-05 frequency reference

missing)

f

f

f

f

7 - 92

D

Braking resistor fault (ON: Resistor overheat or braking transistor fault)

f

f

f

f

--

E

Fault (ON: Faults other than CPF00, CPF01 have occurred.)

f

f

f

f

9 - 2

F

Not used. (Do not set.)

--

--

--

--

--

10

Minor fault (ON: Alarm displayed)

f

f

f

f

9 - 6

11

Fault reset command active

f

f

f

f

--

12

Timer function output

f

f

f

f

7 - 43

13

Frequency agree 2 (Detection width: L4-04)

f

f

f

f

7 - 92

14

Desired frequency agree 2 (ON: Output frequency = L4-03, detection width in L4-04)

f

f

f

f

7 - 92

15

Frequency detection 3 (ON: Output frequency ≦--L4-03, detection width in L4-04)

f

f

f

f

7 - 92

16

Frequency detection 4 (ON: Output frequency ≧--L4-03, detection width in L4-04)

f

f

f

f

7 - 92

8