Set program – station delay time – Irritrol MC-E User Manual

Page 17

Advertising
background image

1

Set Program – Station Delay Time

Station delay time is the adjustable delay period between station operations. The controller’s default station delay is 0

seconds. The maximum delay time you can set between station operation is 4 hours.

Assign Station Delay Time

Step 1 – Place the Function Dial to the SET PROGRAM position.

Step 2 – Enter the program number (1–8) being modified. Press the

to activate the selection.

Press the

button to clear any “Key Entry Error”.

Step 3 – Press the

and

buttons to access the station delay function.

Step 4 – Enter the station delay duration in H MM SS (Hours, Minutes and Seconds) and press

.

To disable the station delay, assign 0 for the time duration.

Example: To assign a 30-second station delay to program 1, enter 0 00 30.

Step 5 – Return the Function dial to AUTO/RUN

position to exit SET PROGRAM.