Elektra Beckum Spindle Moulder TF 100 M User Manual

Page 4

Advertising
background image

7

Commissioning

7.1

1-Phase Power Supply

This machine must be connected to an earthed outlet and operated on a residual current device (RCD) of 30 mA
capacity. Supply voltage required 230V

±

5% 50 Hz. Protect circuit with a fuse 16 A time-lag. A supply line lead

cross section of min. 3 x 2.5 mm

2

is required.

4

7.8

Dust Collector Automatic Start

The electrical installation must provide for automatic starting of the dust collector when the spindle moulder is
switched on, and for a 20 second switch-off delay after the spindle moulder is switched off.

7.7

Dust Collection

This spindle moulder must be connected to a dust collector.
- The fine dust of beech or oak is classified as cancer-causing.
The dust collector this spindle moulder is to be connected to must provide for a minimum air flow rate of
16 m/sec at the machine's dust extraction outlet.
The dust extraction outlet's nominal diameter is 100 mm.

7.6

No-Voltage Release

The switch is equipped with a no-volt release solenoid (magnetic switch) to prevent start-up after a power failure.
It the machine is not connected to the power supply the switch does not engage. In the event of a power failure
the machine has to be restarted by switching ON again.

7.5

Overload Protection

In case of an overload the build-in motor protection relay switches the power off. Let motor cool off for approx.
10 minutes before starting again.

7.2

3-Phase Power Supply

A 5-wire (L1-L2-L3-N-Earth) supply system is required. Connect with the 16A CEE industrial type plug to an
earthed outlet equipped with a residual current device (RCD) of 30 mA capacity. Supply voltage required 400V

±

5% 50 Hz. Protect circuit with 3 fuses 16 A time-lag. A supply line lead cross section of min. 5 x 1.5 mm

2

is

required.

7.3

Direction Of Rotation

For machines with single-phase motor the direction of rotation is factory set. On machines with a three-phase
motor the direction of rotation must be checked after connection to the power supply. Start motor briefly. The
spindle, when viewed from the top, must turn counter-clockwise. To change the direction of rotation interchange
2 of the current conduction leads (black and/or brown). Do not connect the yellow-green earth lead to any of
the current conducting leads.

Note:
With a wrong direction of rotation there is danger of accident. Check direction of rotation carefully.
Have phases interchanged only by a qualified electrician!

7.4

Switch

This spindle moulder is started by actuating the green push-button and
stopped by actuating the red button.

Advertising