Technical Data

Battery unit extension - Panasonic / Sanyo for Powador-gridsave

Page 11

4

Technical Data

Electrical data

Battery voltage [V]

48

Number of battery modules

1

2

3

4

5

Nominal capacity [kWh]

1.35

2.70

4.05

5.40

6.75

Max. charge or discharge output [kWh]

0.70

1.40

2.10

2.80

3.50

Cycles

4000 (at 90% discharge depth)

Service life

15 years

Table 3:

Electrical data

Mechanical data

Ambient temperature for operation [°C]

+5 to +40

Ambient temperature for storage [°C]

-20 … +20 (1 year) … +40 (3

months)

Humidity [%]

<95 (non-condensing)

Cooling

Forced cooling, temp. regulated

Temperature monitoring

Individual monitoring of

components with shutdown in the

event of excess temperature

Maximum installation elevation (m

above mean sea level]

2000

Protection class

IP20

Housing form

19" plug-in module, 2HU

H x W x D [mm] BMS

43x480x475

H x W x D [mm] battery/unit

79x480x400

Weight of BMS [kg]

2.5

Weight per battery/unit [kg]

19

Table 4:

Mechanical data