Chapter 3, Motherboard information – Lanner LEC-3000A User Manual

Page 13

Advertising
background image

11

Motherboard Information

Chapter 3

Embedded and Industrial Computing

SW2/SW3/SW4/SW5: These switches — SW2, SW3, SW4

and SW5 — are used to adjust the serial port type for

COM1, COM2, COM3, and COM4 respectively Use the

table below as the switch adjustment information for

COM1 through COM4

COM Port No.

Port Type

COM 1

COM 2

COM 3

COM 4

RS-232

Switch 2:

1 ON

2 OFF
3 OFF
4 OFF

Switch 3:

1 ON

2 OFF
3 OFF
4 OFF

Switch 4:

1 ON

2 OFF
3 OFF
4 OFF

Switch 5:

1 ON

2 OFF
3 OFF
4 OFF

RS-422

Switch 2:

1 OFF

2 ON
3 ON

4 OFF

Switch 3:

1 OFF

2 ON
3 ON

4 OFF

Switch 4:

1 OFF

2 ON
3 ON

4 OFF

Switch 5:

1 OFF

2 ON
3 ON

4 OFF

RS-485

Switch 2:

1 OFF

2 ON

3 OFF

4 ON

Switch 3:

1 OFF

2 ON

3 OFF

4 ON

Switch 4:

1 OFF

2 ON

3 OFF

4 ON

Switch 5:

1 OFF

2 ON

3 OFF

4 ON

SW6/SW7/SW8/SW9: These switches — SW6, SW7,

SW8 and SW9 — are used to enable or disable the

signal termination for COM1, COM2, COM3, and

COM4 respectively Use the table below for the switch

adjustment information for COM1 through COM4 We

strongly recommend that you disable termination when

the port is configured as RS-232 and enable it when the

port is configured as RS-485/RS-422

CMOS1: This jumper provides a means to return the BIOS

settings to its default state automatically on power-up

SPI-ROM(J1): Using the appropriate cable to connect this

10-pin ISP in header connector, the user can update the

SPI Flash soldered on board

CN1: Connector CN1 provides access to the COM1

through COM4 serial port’s data transmission when the

port is configured for either RS-422/RS-485 or RS-232 serial

protocol The signals present on each of the connector’s

pins for these three modes can be referenced in Front

Panel Features, Chapter 1 Introduction The COM ports'

serial protocol mode is configured using the following

dip switches: SW2, SW3, SW4, and SW5 In addition, when

used as in RS-485 mode, the system can automatically

detect the direction of incoming data and switches its

transmission direction accordingly - the automatic data

flow control in RS-485 Hence, no handshaking signal (RTS

signal) is necessary This allows you to conveniently build

an RS-485 network with just two wires More significantly,

application software previously written for half duplex

RS-232 environments can be maintained without

modification

USBF1: Dual USB Interface Connector (USB No 4 and

No 5): It is used for connecting the USB module cable

It complies with USB2 0 and support up to 480 Mbps

connection speed

CF1: A Compact Flash Connector It is used for connecting

a Compact Flash card to serve as your system's storage

CN1(on DC/DC converter board): A power socket for a

power supply through Phoenix Contact

ON

1 2 3 4

3 2 1

Pin No.

Function

Short 1-2

Normal (Default)

2-3

Clear CMOS

Pin No.

Function

2

RSVD

4

+3.3V

6

RSVD

8

SPI_CLK

10

SPI_MOSI

Function

Pin No.

SPI_HOLD_N

1

SPI_CS0_N

3

SPI_MISO

5

RSVD

7

GND

9

1
3
5
7
9

2
4
6
8

10

Pin Name

Pin No.

USB_VCC4

1
3

USBD4N

5

USBD4P

7

GND

9

Pin No.

Pin Name

2

GND

4

USBD5P

6

USBD5N

8

10

USB_VCC5

1
3
5
7

9

2
4
6
8

10

Pin No.

1

2

Function

Ground

DC=In

12

ON

OFF

COM
Port No.

Port Type

COM 1

COM 2

COM 3

COM 4

RS-232

Switch 2:

1 ON

2 OFF
3 OFF
4 OFF

Switch 3:

1 ON

2 OFF
3 OFF
4 OFF

Switch 4:

1 ON

2 OFF
3 OFF
4 OFF

Switch 5:

1 ON

2 OFF
3 OFF
4 OFF

RS-422

Switch 2:

1 OFF

2 ON
3 ON

4 OFF

Switch 3:

1 OFF

2 ON
3 ON

4 OFF

Switch 4:

1 OFF

2 ON
3 ON

4 OFF

Switch 5:

1 OFF

2 ON
3 ON

4 OFF

RS-485

Switch 2:

1 OFF

2 ON

3 OFF

4 ON

Switch 3:

1 OFF

2 ON

3 OFF

4 ON

Switch 4:

1 OFF

2 ON

3 OFF

4 ON

Switch 5:

1 OFF

2 ON

3 OFF

4 ON

Termination

(Enable/dis-
able)

Switch 6:

Enable ON

Disable: OFF

Switch 7:

Enable ON

Disable: OFF

Switch 8:

Enable ON

Disable: OFF

Switch 9:

Enable ON

Disable: OFF

OFF

Advertising