1.

Fireplace won't light when the piezo ignitor is depressed.
a.

With the gas tuned off depress the piezo ignitor to check the
spark. You should see a spark jump from tip of the electrode.
If there is a spark, check the gas supply. Is the tank full? Is
the line purged of air? Can you light the burner with a
match?

b.

Check air shutter adjustment, close as needed.

c.

Check the orifice for blockage.

d.

Is the electrode tip clean and free from debris?

e.

Clean electrode tip.

2.

Burner flame is yellow or orange and there is a smell of gas.
a.

Check the burner inlet for obstructions.

b.

Check the air shutter for proper adjustment.

c.

Check for spiders, spider webs and debris.

3.

Low heat with control knob set on "HI."
a.

Is the fuel hose bent or kinked?

TROUBLE-SHOOTING

If your outdoor gas fireplace does not function properly, use the following checklist for possible solutions.

b.

Is there an adequate gas supply?

c.

Does the orifice or burner need cleaning?

d.

Is the air shutter too far open or closed?

e.

Is the gas supply, or gas pressure low?

4.

The smell of gas with flames appearing sooty yellow.
a.

Check for spiders or insects.

b.

Spiders and insects can nest in the burner and cause a
disruption in the flow of gas from the burner. This is
dangerous and can cause a fire behind the valve cover,
damaging the outdoor gas fireplace and making it unsafe to
operate.
You should inspect the burner immediately if any of these
conditions occur or persist.

5.

The burner makes popping noises.
a.

Check air shutter adjustment.

b.

Check burner for clogged ports.

PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.

Index

Part

No.

Number

Description

Index

Part

No.

Number

Description

1

R-5647

BOTTOM LOG

2

R-5649

RIGHT CROSS LOG

3

R-5648

LEFT CROSS LOG

4

R-5634

RAIN CAP WITH KNOB AND
HANGER CLIP - RED

4

R-5659

RAIN CAP WITH KNOB AND
HANGER CLIP - GREEN

5

R-5631

CHIMENEA STACK CASTING -
RED

5

R-5657

CHIMENEA STACK CASTING -
GREEN

6

R-5630

CHIMENEA BODY CASTING -
RED

6

R-5656

CHIMENEA BODY CASTING -
GREEN

7

R-5651

DOOR SCREEN

8

R-5633

LEG WITH RUBBER FEET - RED
(3 REQ’D)

8

R-5658

LEG WITH RUBBER FEET -
GREEN (3 REQ’D)

9

R-5636

BURNER ASSEMBLY

9.1

R-5909

CAST BURNER ASSEMBLY
WITH PIPE AND VENTURI

9.2

R-5638

VALVE COVER

9.3

R-5639

ORIFICE - LPG

9.4

R-5640

ORIFICE - NAT

9.5

R-5641

SAFETY VALVE

9.6

R-5642

THERMOCOUPLE

9.7

R-3992

REGULATOR HOSE ASSEMBLY
- LPG (26")

9.8

R-2708

PIEZO IGNITOR

9.9

R-5908

ELECTRODE AND WIRE
ASSEMBLY

9.10

R-5644

LABEL SET ON CHAIN
(ATTACHED TO VALVE COVER)

9.11

R-3357

VALVE SPRING

9.12

R-3358

AIR SHUTTER

9.13

R-5645

VALVE KNOB

10

R-5653

TANK SECURING HOOK WITH
BOLT, WASHER AND NUT

NOT SHOWN R-5635

STACK RESTRICTOR PLATE

NOT SHOWN R-5646

BURNER MOUNTING BAR

NOT SHOWN R-5650

FLICKER SHIELD (2 REQUIRED)

NOT SHOWN R-5913

IGNITOR BRACKET

Advertising