CLEARANCES

Minimum Clearances From Combustible Construction
(Figures 2 and 3)
Side

6"

Rear

6"

Top

47" from top of unit or 96" from floor

Floor

Combustible

Minimum Clearances From Combustible Construction with
20 lb. Propane (LP) Tank Attached to Outdoor Gas Fireplace
(Figure 4)
Side

6"

Side, Corner Installation 7"
Top

47" from top of unit or 96" from floor

Floor

Combustible

Warning: When selecting a location for your outdoor chimenea,
it is important to consider that any ceiling, overhang or other
surface located above the chimenea can discolor due to heat or
carbon particles generated while unit is operating.

Attention: Rain cap must be placed on outdoor chimenea when
not in use. Rain cap will prevent rain from entering top of
chimenea. Without rain cap in place, rain can wash soot off logs
on burner. Soot from logs will stain your patio or deck.