3.4 ALARM SETUP MENU

In the ALARM SETUP MENU, we define :

(1) ALARM:

ENABLE: Enable alarm detection.

DISABLE: Disable alarm detection.

(2) ALARM TYPE:

N. O. : Normal Open alarm.

N. C. : Normal Close alarm.

(3) ACTIVE CAMERA:

Active camera setting, from camera 01~08. You can set the camera which corresponds to the

place where the alarm is located.

Note: The recording camera number in an event depends on the alarm number, and the active camera

images will not be recorded. Example: You assign camera 3 as the active camera to alarm 1.

When the alarm 1 is triggered, camera 3 will be displayed and camera 1 will be recorded.

(4) RETRIGGER: Re-trigger the alarm.

YES : The duration time starts when an alarm is triggered. The duration time restarts from 0 when a

new alarm is triggered during an alarm action.

NO: The alarm signal will not be triggered again during duration time.