3.5 MOTION SETUP MENU

In the MOTION SETUP MENU, we define :

(1) MOTION:

ENABLE: Enable motion detection.

DISABLE: Disable motion detection.

Note: Motion only works in live and playback modes. It is invalid when you are setting menus.

(2) SENSITIVITY:

The sensitivity allows users to adjust to a suitable motion detection sensitivity. There are 10

sensitivities available; level 1 is the lowest, and level 10 is the highest sensitivity.

(3) RETRIGGER: Re-trigger the alarm.

YES : The duration time starts or restarts when an alarm is triggered. The duration time restarts

from 0 when a new alarm is triggered during an alarm action.

NO: The alarm signal will not be triggered again during duration time.

(4) DURATION:

Buzzer noise and event record duration of an alarm, from 1 sec to 99 seconds. The default value is

5 seconds.

(5) ALARM OUTPUT:

The setting of alarms which are NONE and 1, where 1 means the alarm is enabled.

38