Remote control / operation, Remote control – EverFocus esrd EDSR-900 User Manual

Page 49

Advertising
background image

RJ45 (RS -485) pin assignment

11. REMOTE CONTROL

11.1 RS-485 REMOTE CONTROL

The new standard EverFocus EDSR remote control protocol allows sophisticated installations with
DVR remote control at different installation sites.
EDSR remote control is supported by the keyboards KS KBJ (with 3-axis joystick and 2 additional
RS-485 ports for telemetry control with independent telemetry protocols) and KS KBK (no telemetry).
Up to 32 units are allowed in the RS -485 bus. The RS -485 bus requires serial wiring with 2-wire
shielded twisted pair cable (“daisy chain”). Maximum cable length of the bus is 1200 m.
Star wiring is only possible with additional RS -485 distributor.
Mixed installation is possible with following recorder types:
EDSR 100 M, EDSR 400 M, EDSR 600, EDSR 900, EDSR 1600
For installation details, please refer to the KS-KBK and KS-KBJ keyboard manuals.

Installation example (2 remote operators, 1 EDSR 900, 1 EDSR 1600) :

1 2

3

4 5

6

7 8

There are two RJ-45 (RS-485) connectors on the back panel of the DVR (loop-through). For
application, please refer to the following pin assignment.

RS-485 2 wire

RS-485 2 wire

RS-485 2 wire

Video 5 x

Video 5 x

Video 1 x

Video 1 x

CALL 1 CALL 2

MAIN1 M1-1 M1-2 M1-3 M1-4

MAIN2 M2-1 M2-2 M2-3 M2-4

Operator 1:
1x Full screen view DVR1
1x Full screen view DVR2

Operator 2:
1x Multi screen view DVR1 (MAIN)
4x Full screen view DVR1 (MATRIX)
1x Multi screen view DVR1 (MAIN)
4x Full screen view DVR2 (MATRIX)

DVR1: EDSR1600

DVR2: EDSR900

NC

8

NC

7

RX -

6

NC

5

NC

4

RX +

3

NC

2

GND

1

FUNCTION

PIN

44

REMOTE CONTROL / OPERATION

Advertising