Instruction manual, Caution – Emerson Process Management FISHER 657 User Manual

Page 4

Advertising
background image

Instruction Manual

D100306X012

657 Actuator (30-70 and 87)

December 2010

4

Figure 3. Actuator Mounting Components for Size 30 through 70 Actuators

VALVE STEM

YOKE LOCK NUT

YOKE BOSS DIAMETER

BONNET

TYPICAL VALVE
(REFER TO VALVE MANUAL)

W6199-1

MATCH LINE
FOR ACTUATOR

NPT INTERNAL CONNECTION

DIAPHRAGM CASING

DIAPHRAGM AND STEM
SHOWN IN UP POSITION

DIAPHRAGM PLATE

ACTUATOR SPRING

ACTUATOR STEM

SPRING SEAT

SPRING ADJUSTOR

STEM CONNECTOR

YOKE

TRAVEL INDICATOR DISK

INDICATOR SCALE

W0363-1

LOWER DIAPHRAGM CASING

CAUTION

To avoid parts damage, do not use an operating pressure that exceeds the Maximum Diaphragm Casing Pressure (table 1)
or produces a force on the actuator stem greater than the Maximum Allowable Output Thrust (table 1) or the maximum
allowable valve stem load. (Contact your Emerson Process Management sales office with questions concerning maximum
allowable valve stem load.)

D Valve/Actuator Assembly: If the actuator and valve are shipped together as a control valve assembly, it has been

adjusted at the factory, and may be installed in the pipeline. After installing the valve in the pipeline, refer to the
Loading Connection procedures.

Advertising