Troubleshooting, Indicators, Error indicators and warning messages – Casio XJ-H2600 User Guide User Manual

Page 51

Advertising
background image

51

Troubleshooting

Indicators keep you informed about the current operational status of the projector. The following
shows what the indicators look like when operation is normal.

When a warning message appears on the projection screen, or when the POWER/STANDBY, LIGHT,
and TEMP indicators are lit or flashing in a pattern other than those shown above, it means that a
projector error has occurred. For details, see “Error Indicators and Warning Messages” (below).

Warning messages and indicators let you know what the problem is when a projector error occurs.
When an error occurs, wait until the fan stops before unplugging the AC power cord. If you unplug the
AC power cord while the fan is still operating, an error may occur when you plug the AC power cord
back in.

Indicators

When the indicators appear

like this:

It means this:

POWER/

STANDBY

LIGHT

TEMP

You have just plugged the AC power cord into a power outlet. Wait until the
projector enters the standby state (see below) before trying to turn on power.

z

z

z

Amber

Amber

Amber

z

c

c

Standby state: The AC power cord is plugged in and the projector is in standby.

Amber

z

z

Projector is warming up after being turned on.

Green

Amber

Amber

z

c

c

Projector is on and standing by for use.

Green

c

c

Projector is performing internal power down processes.

Amber

z

z

c

“On (Auto)” or “On (Manual)” is selected for the projector’s Eco Mode (page 25)
setting.

Green

Green

z

: Lit

: Flashing

c

: Unlit

Error Indicators and Warning Messages

Indicator/Error Message

Description and Required Action

POWER

: Green steady

The projector’s internal temperature is very high. Press the [ESC] key to
clear the warning message and perform the following steps.

1 Check for any blocking of the projector’s vents, and make sure that

there is sufficient space around the projector. See

Setup Precautions

(page 11).

2 If there is dust accumulated around the vents, turn off the projector and

remove it. See

Cleaning the Projector” (page 50).

LIGHT

: –

TEMP

: –

Message

: Internal temperature is too

high. Check projector air
vents for blockage.