Command/response table for sis commands, Symbol definitions – Extron Electronics MAV Plus Series User Manual

Page 114

Advertising
background image

4-7

CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide

Command/Response Table for SIS Commands

Symbol Definitions:

= Carriage return/line feed

= Carriage return (no line feed)

= Space

Esc

= Escape key

Input and output numbers in commands may be entered as either 1-digit, 2-digit, or 3-digit

numbers. All input and output numbers are reported as 2-digit numbers in the response.

X1

= Input number

01 – (maximum number of inputs for your model)

X2

= Input number (for tie)

00 – (maximum number of inputs) (00 = untied)

X3

= Output number

01 – (maximum number of outputs for your model)

X4

= Numeric dB value

–18 to +24 (45 steps of gain or attenuation)

X5

= Audio gain

0 – 24 (1 dB/step)

X6

= Audio attenuation

1 – 18 (1 dB/step)

X7

= Volume adjustment range

0 – 64 (1 dB/step except for 0-to-1, which is 13 dB)

X8

= Room # (for room presets)

10 max. (each can have up to 10 presets (

X12

s) assigned)

A Room is a subset of operator-selec ted outputs that relate to each other. The CrossPoint 450 Plus

or MAV Plus switcher supports up to 10 rooms, each of which can consist of from 1 to 16 outputs.

X9

= Mute, Lock mode, power supply

(0 = off/mode 0/not Ok, 1 = on/mode 1/Ok, 2 = mode 2)

X10

= Group # (for I/O grouping)

1 through 4 groups (0 = no group)

X11

= Global preset #

0, 01-32 maximum (0 = current configuration)

X12

= Room preset #

10 maximum (0 = current configuration for room)

A Room preset is a stored configuration with all of the outputs assigned to a single room.

When a room preset is retrieved from memory, it becomes the current configuration.

X13

= RGB delay interval

Delay in ½ second increments (10 maximum)

X14

= Video/audio mute:

0 = no mutes
1 = video mute
2 = audio mute
3 = video and audio mute

X15

= Sync frequency

xxx.xx (frequency in Hz (V) or kHz (H))

X16

= Connection status

0 = no input connected
1 = input connected

X17

= Firmware version number to second decimal place (x.xx)

X18

= Verbose firmware version-description-upload date/time. See page 4-16.

X19

= Name

12 characters maximum for input, output, global preset,
and room preset names.
11 characters maximum for room names.
Upper- and lower-case alphanumeric characters and
_ / and spaces are valid.

The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.

X20

= Voltage

Positive or negative voltage and magnitude

X21

= Temperature

Degrees Fahrenheit

X22

= Fan speed

RPM

Advertising