Extron Electronics MAV Plus Series User Manual

Page 94

Advertising
background image

3-51

CrossPoint 450 Plus and MAV Plus Switchers • Operation

Selecting the rear panel Remote port protocol and baud rate

This procedure affects the rear panel Remote port only. The front panel
Configuration (RS-232) port’s variables can be changed under serial port or
Ethernet control only. See the Command/Response table for IP SIS commands,
in chapter 4, “Programmer’s Guide”, to configure either port under SIS
control.

The Remote port settings are protected when front panel lock mode 2 is
selected. You can view the settings in
lock mode 2, but not adjust them from
the front panel.

The switcher can support either RS-232 or RS-422 serial communication protocol,
and operate at 9600, 19200, 38400, and 115200 baud rates. The settings of these
variables can be viewed and changed from the front panel.

View and configure the switcher’s serial communications settings as follows:

1

.

To enter Serial Port Configuration mode, simultaneously press and hold all
Control buttons (Enter, Preset, View, and Esc) (figure 3-79).

The flashing Control button indicates the baud rate as follows:
Enter — 9600

Preset — 19200

View — 38400

Esc — 115200

The flashing I/O button indicates the protocol as follows:
RGBHV/Video — RS-232

Audio — RS-422/RS-485

In this example, the port is set to RS-232 at 9600 baud.

Press and hold the Enter, Preset,

View, and Esc buttons

.

All Control buttons light with
one flashing.

Both I/O buttons light
with one flashing.

2 seconds

I / O

RGBHV

AUDIO

C O N T R O L

PRESET

ENTER

ESC

VIEW

C O N T R O L

PRESET

ENTER

ESC

VIEW

Figure 3-79 — RS-232/RS-422 and baud rate display

2

.

Release the Control buttons.

Advertising