Rear panel controls, Performing soft system resets – Extron Electronics MAV Plus Series User Manual

Page 96

Advertising
background image

3-53

CrossPoint 450 Plus and MAV Plus Switchers • Operation

Rear Panel Controls

The rear panel has a Reset button that initiates four levels of matrix switcher resets.
Press and hold the button while the switcher is running or while you apply power
to the switcher for different reset levels.

Performing soft system resets

The CrossPoint 450 Plus and MAV Plus switchers have three soft resets available
that restore various tiers of switcher settings to their default settings.

Events (mode 3) reset —

This function toggles the monitoring of events on or

off (if events monitoring was on, this function turns it off; if it was off, it is
turned on).

IP settings (mode 4) reset —

The IP settings reset performs the following

functions:

Enables Arp program capability

Resets the IP address to the factory default (192.168.254.254)

Resets the subnet mask to the factory default (255.255.0.0)

Resets the gateway address to its factory default (0.0.0.0)

Turn DHCP off

Turn events off

IP settings reset does not replace any user-installed firmware.

Absolute (mode 5) reset —

Absolute reset restores the switcher to the default

factory conditions. This function is identical to the

Esc

ZQQQ

SIS

command, see chapter 4, “Programmer’s Guide”).

Perform a soft reset of the switcher as follows:

Advertising