Cleaning and maintenance, Cleaning, Lubrication – Powerplus POWX154 B ENCH DRILL 500W EN User Manual

Page 9: Technical data, Noise, Service department

Advertising
background image

POWX154

EN

Copyright © 2013 VARO

P a g e

| 9

www.varo.com

10 CLEANING AND MAINTENANCE

Attention !Before performing any work on the equipment, pull the power
plug.

10.1

Cleaning

 Keep the ventilation slots of the machine clean to prevent overheating of the engine.
 Regularly clean the machine housing with a soft cloth, preferably after each use.
 Keep the ventilation slots free from dust and dirt.
 If the dirt does not come off use a soft cloth moistened with soapy water.

Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.

10.2

Lubrication

 Turn the drill shaft to the maximum drilling depth once per 3 months and grease it slightly

with oil.

11 TECHNICAL DATA

POWX154

Mains voltage

230V

Mains frequency

50Hz

Power input

500W

No-load speed

425-2545 min-1

Number of drilling speeds

12

Chuck capacity

1,5 - 16mm

Table dimensions

200 x 200 mm

With extensions

240(330)x200mm

Pillar height

850mm

Weight

35,2 kg

Cross laser

yes

12 NOISE

Noise values measured according to relevant standard. (K=3)
Acoustic pressure level LpA

65 dB(A)

Acoustic power level LwA

78 dB(A)

ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).

13 SERVICE DEPARTMENT

Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by a
qualified person (qualified electrician).

Advertising