4

Enerco Group, Inc.,| Gas-Fired Low-Intensity Infrared Heater

Operating Instructions and Owner’s Manual

- Rear View -

Rear Movable Hanger

Heat Exchanger

Reflector

Front Fixed Hanger

About The Heater

Burner Box

Control Side
Access

Burner Box

Contains the electrical components (i.e. blower motor, power transformer, etc.) and gas distribution components
(i.e. gas valve, etc.) that make the heater work. There are no owner serviceable items contained in this box.

Front Fixed Hanger

Provides rigid support and mounting surface for the reflector. Holes are provided in the upper corners of the

bulkhead to accommodate suspension hardware required for installation of the heater.

Reflector

The reflector is made from formed aluminum and reflects the radiant energy downward to the space to be

heated.

Heat Exchanger

A U-shaped tube through which the heated products of combustion pass.

Rear Movable Hanger

Provides support for the heat exchanger and reflector at the end that is furthest from the burner box. The

support may be moved (within limits) to accommodate hanging of the unit.

Service Door

To be removed only by a licensed contractor. Removal of this service door provides access to the electrical and

gas distribution components.

Intake Vent

Accomondates a 3" diameter combustion air inlet duct that delivers fresh air to the burner.

Exhaust Vent

Accomondates the air-venting duct that carries the products of combustion to be vented outdoors.

Nipple – ½ NPT

Point at which the gas supply is connected to the heater.

Power Cord

Includes a three prong plug that must be connected to a dedicated and properly grounded three prong ceiling
outlet.

Exhaust Vent

Intake Vent

1/2" NPT

Power Cord