Technical specifications: - side view - - end view, Heater specifications, Venting specifications – Enerco HST45 User Manual

Page 5

Advertising
background image

5

Operating Instructions and Owner’s Manual

| Gas-Fired Low-Intensity Infrared Heater

Leading Particulars

Model No.

BTU/hr

Weight

Length

MHT- 45

45,000

96 lbs.

10’

Technical Specifications:

- Side View -

- End View -

Reflector

Heat
Exchanger

Suspension Points

1" Max.

11

1/2"

Burner Box

13

1/2

"

9"

HEATER SPECIFICATIONS

Electrical

Rating: 120VAC, 60Hz, single phase, 1 amp

Connection: 3 pin molded plug

Gas Inlet Connection

Connection ½” Male NPT

Gas Inlet Pressure
The minimum inlet gas supply pressure for the purpose of input
adjustment.

Natural Gas:

Minimum - Inlet 5.0” w.c.

Maximum - Inlet 10.5” w.c.

LP Gas (propane):

Minimum - Inlet 11.0” w.c.

Maximum – Inlet 13.0” w.c.

Manifold Pressure

Natural Gas: 4.0” w.c.

LP Gas (propane): 10.0” w.c.

VENTING SPECIFICATIONS

Vent/Flue

Length – 25 feet (Maximum)

5 feet (Minimum)

Flue Pipe – 3.0” diameter

Vent Pipe – 3” diameter

Length