Combustible material fireplace preparation – Empire Comfort Systems VFSR-24-3 User Manual

Page 11

Advertising
background image

26333-3-1210

Page 11

FOr MASONry BuILT FIrePLAceS

Free OPeNING AreA OF cHIMNey DAMPer FOr VeNTING

cOMBuSTION PrODucTS FrOM DecOrATIVe APPLIANceS

FOr INSTALLATION IN SOLID FueL BurNING FIrePLAceS

Turn off gas supply to fireplace or firebox.

Have the fireplace floor and chimney professionally cleaned to

remove ashes, soot, creosote or other obstructions. Have this

cleaning performed annually after installation.

Seal any fresh air vents or ash clean-out doors located on floor

or wall of fireplace. If not, drafting may cause pilot outage or

sooting. Use a heat-resistant sealant. Do not seal chimney flue

damper.

Install and operate the appliance as directed in this manual.

FOr FAcTOry BuILT FIrePLAceS

Free OPeNING AreA OF cHIMNey DAMPer FOr VeNTING

cOMBuSTION PrODucTS FrOM DecOrATIVe APPLIANceS

FOr INSTALLATION IN SOLID FueL BurNING FIrePLAceS

Do not attach combustible material to the mantel of your fireplace.

This is a fire hazard.

Figure 7

No greeting card, stockings or ornamentation of any type should be
placed on or attached to the fireplace. This is a heating appliance.
The flow of heat can ignite combustibles.

Figure 8

cOMBuSTIBLe MATerIAL

FIrePLAce PrePArATION

Appliance Input rate (BTu/hr)

20

30

40

chimney

Height* (ft)

Minimum Opening** (sq. in.)

10

11.3

16.6

22.1

15

8.6

12.6

17.3

20

7.5

10.8

14.5

25

6.6

9.6

12.6

30

6.2

9.1

11.3

35

5.7

8.0

10.8

40

5.3

7.5

10.2

* Height is from hearth to top of chimney and the minimum height

is 10 feet.

** Chart shows minimum opening (sq. in.) for given height and

input rate.

Appliance Input rate (BTu/hr)

20

30

40

chimney

Height* (ft)

Minimum Opening** (sq. in.)

6

17.6

25.7

33.8

8

16.5

23.7

31.2

10

15.1

21.7

28.7

15

14.1

19.9

26.1

20

12.9

18.5

23.7

30

12.2

16.9

21.6

* Height is from hearth to top of chimney and the minimum height

is 6 feet.

** Chart shows minimum opening (sq. in.) for given height and

input rate.