Page 16

A. This appliance has a pilot which must be lighted by

hand. When lighting the pilot, follow these instructions

exactly.

B. BeFOre LIGHTING smell all around the appliance area

for gas. Be sure to smell next to the floor because some

gas is heavier than air and will settle on the floor.

wHAT TO DO IF yOu SMeLL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch;

do not use any phone in your building.

• Immediately call your gas supplier from a neighbor's

phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control

knob. Never use tools. If the knob will not push in or

turn by hand, don't try to repair it; call a qualified service

technician. Force or attempted repair may result in a fire

or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect

the appliance and to replace any part of the control system

and any gas control which has been under water.

Notice: For easy access to valve for lighting pilot, remove branch

log and middle log from burner

assembly before lighting.

1. STOP! Read the safety

information.

2. Push in gas control knob

slightly and turn clockwise

to the “OFF”

position. Do not force.

3. Turn gas flow adjustment

knob clockwise

either manually or with

remote control to “OFF”.

4. Wait ten (10) minutes to

clear out any gas. Then

smell for gas, including near

the floor. If you smell gas

STOP! Follow “B” in the

safety information. If you do

not smell gas, go to the next

step.

5. Find pilot - the pilot is attached

to rear of burner.

6. Turn gas knob counterclockwise

to “IGN”.

7. Depress and turn gas control knob counterclockwise

to “PILOT”. A spark is produced when gas control knob is

turned between “IGN” and PILOT”. Repeatedly depress and

turn gas control knob between “IGN” and PILOT” until pilot is

ignited. Continue to hold the control knob in for about one (1)

minute after pilot is lit. Release knob and it will pop back up.

Pilot should remain lit. If it goes out, repeat steps 2 through

7.

If the knob does not pop out when released, stop

and immediately call your service technician or gas

supplier.

If the pilot will not stay lit after several tries, turn the gas

control knob to OFF and call your service technician.

8. Attention! Gas control has an INTERLOCK latching device.

When the pilot is initially lit and the safety magnet is

energized (pilot stays on ) the INTERLOCK latching device

becomes operative. If the gas control is turned to the “OFF”

position or gas flow to the appliance is shut off, the pilot

cannot be relighted until the safety magnet is de-energized

(approximately 60 seconds). There will be an audible “click”

when he safety magnet in the gas control is de-energized.

Pilot can now be relighted. Repeat steps 2 through 7.

9. Turn gas control knob counterclockwise

to “ON”.

10. Turn gas flow adjustment knob counterclockwise

either manually or with remote control between “OFF” and

“ON” to adjust flame height.

1. Turn gas flow adjustment knob clockwise

either

manually or with remote control to “OFF”.

2. Push in gas control knob slightly and turn clockwise

to “OFF”. Do not force.

FOR YOUR SAFETY READ BEFORE LIGHTING

VFSV-(16,18,24,30) LIGHTING INSTRUCTIONS

wArNING: If you do not follow these instructions exactly, a fire or explosion may

result causing property damage, personal injury or loss of life.

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE