Concrete ceilings, Wooden ceiling joists, Truss ceilings – Extron electronic PROJECTOR CEILING MOUNT PCM 240 User Manual

Page 6: Installation, cont’d

Advertising
background image

7

2.

Tap the concrete anchors into the drilled holes, until the

head is seated against the ceiling material.

3.

Using the claw on the hammer or a pair of pliers, pull down

firmly on each of the anchors. This will set and secure the

anchors in place.

Drill hole

Secure tie wire

Pull down

Tap in anchor

Figure 4 — Installation sequence for concrete
ceiling anchors

Wooden ceiling joists

1.

Mark and drill four holes, approximately 1¼" (32 mm) deep

into the ceiling joists, using a 5/16" (8 mm) diameter drill

bit.

2.

Screw in the eye screws until they are secure.

N

The eye screws should not be screwed in directly above

where the turnbuckles attach but offset about 10 degrees

out from vertical (see figure 2).

1. Drill Pilot

Hole

2. Screw in

Eye Screw

Secure

Tie Wire

Figure 5 — Installation sequence for wood joist
screws

Truss ceilings

Follow the steps in “Attaching the tie wire” section on page 8.
N

The point in the ceiling at which the wire is to be attached

should not be directly above where the turnbuckles

attach, but offset about 10 degrees out from vertical.

PCM 240 Projector Ceiling Mount • Installation

W.

For safety, all wiring of the electrical boxes and
accessories should be completed after the plate is
fully installed and secure.

9.

Place the mounting plate back over T-bar rails, so that

the hole in the tile aligns with the pipe adapter plate. If

necessary, loosen the lock nuts on the pipe adapter plate

and readjust the plate to align over the hole. If you wish

to fit the anti-vibration pads, follow step 10 below. If not,

just tighten down the lock nuts and proceed to step 13.

N

DO NOT rest, or lean on the mounting plate or

suspended ceiling grid when attaching turnbuckles, tie

wire, or drilling into ceiling.

10.

To mount the four optional self adhesive anti-vibration

pads, completely unscrew the lock nuts on the adapter

plate, and remove the top section only.

11.

Peel and attach the pads to the underside of the adapter

plate, one near each corner (see figure 3).

Attach Anti-vibration
Pads Here

Attach Anti-vibration
Pads Here

Figure 3 — Attach anti-vibration pads under
adapter plate

12.

Replace top adapter plate and secure in place with locking

nuts.

13.

Attach the four turnbuckles to the long sides of the

mounting plate, one near each corner (see figure 2).

Securing the mounting plate to the structural ceiling

Follow the steps below, according to the structural ceiling type,

and preferred method.

Concrete ceilings

1.

Mark and drill four holes, at least 1½" (38 mm) deep, into

the ceiling, using a ¼" (6 mm) diameter carbide tipped drill

bit.

N

These holes should not be drilled directly above where

the turnbuckles attach, but offset about 10 degrees out

from vertical (see figure 2).

Installation, cont’d