Attaching the tie wire, Threaded rod installation, Attaching the safety cable – Extron electronic PROJECTOR CEILING MOUNT PCM 240 User Manual

Page 7: Installation, cont’d

Advertising
background image

PCM 240 Projector Ceiling Mount • Installation

8

Installation, cont’d

Attaching the tie wire

1.

Cut four equal lengths of wire, sufficient to be terminated

at both ends (at ceiling and turnbuckles) with at least five

loops around itself.

2.

Loop the wire through the anchors, eye screws, or over the

truss, and twist the wire around itself at least five times.

Figure 6 — Anchor and screw tie wire fastening

N

The final loop should be tightly bent and secured to the

wire to avoid untwisting under stress.

3.

Loop the wire through the turnbuckles, twisting the wire

around itself at least five times to secure it.

4.

Using a wrench, adjust the turnbuckles to take up slack,

and to level the ceiling plate so it just rests on the grid. The

four support wires should be taut, and should take the full

weight of the completed installation.

5.

Tighten the T-bar securing screws fully.

Threaded rod installation

If threaded rods (not supplied) are to be used instead of the

supplied tie wire to secure the plate to the ceiling, insert the

threaded rods through the holes at the ends of plate. Secure

with washers and nuts. Adjust the length as needed to ensure

the plate remains level and so it just rests on the T-bar. The rods

should take the full weight of the completed installation.

Insert threaded rods
through holes on the
ends of the
mounting plate.

Attach Washer and Nut and Secure

Figure 7 — Installing threaded rods on the PCM 240

Attaching the safety cable

As an added precaution, the supplied safety cable must be

installed. This will help hold the mount up in the event that any

of the tie wires, or threaded rods come loose or detach during an

earthquake or accident.
To install the safety cable, follow the steps below:
1.

When the projector ceiling mounting plate is attached to

the structural ceiling and rests on the T-bar, find and mark

a point directly above the plate’s center.

C

DO NOT rest, or lean on the plate or suspended
ceiling grid during installation of safety cable, or
during installation and wiring of electrical boxes,
accessories and projector.

2.

At the marked location, drill a hole and install a ceiling

anchor or eye screw, following the steps in “Securing the

mounting plate to the structural ceiling” on page 6.

3.

Pass the safety cable through the anchor and attach it with

even lengths to the center holes on either side of the plate.

Secure using the cable clamps.

Attach safety cable
to center holes and
secure with cable clamps.


Figure 8 — Attach safety cable to the ceiling and
the PCM 240

N

As more items are installed (electrical boxes, projector,

and pole etc.), the tire wire and safety cable may become

stretched or may loosen under the combined weight.

Upon completion of the entire installation, and

periodically afterwards, carefully check the cable

clamps, safety cable, tie wire, and ceiling anchors

to ensure they are properly secured and are taking

the full weight of the installation.

PCM 240 Projector Ceiling Mount • Installation

9