9. TROUbLESHOOTING

PRObLEM

POSSIbLE

CAUSES REMEDY

engine will not start

low oil sensor has shut down engine

Top up oil to correct level

engine switch not in the ON position

Turn switch ON

Pressure

build-up

in

pump

Operate

trigger

engine is overloaded

Nozzle partially blocked

Clean nozzle

excessive pressure build-up

Return to dealer to have reflux valve adjusted

engine running but pump not

Mains water turned off

Turn on mains water

building maximum pressure or has

irregular pressure

Unit has been stored in freezing temperatures

Thaw out completely including hose, gun and wand

Inadequate water supply

MInimum required is 10ltr/min at 20psi

Water

inlet

filter

clogged

Clean

filter

Kink in water supply hose

Straighten hose

Wand nozzle worn or damaged

Replace nozzle

Air in pump

Run unit with gun open and wand removed until

air

is

purged

Suction or discharge valve clogged or worn out Clean suction or discharge valves

Bypass valve not operating effectively

Clean bypass valve

No intake of chemicals

Injection tube not properly attached to unit

Push tube firmly onto siphon nozzle

Tube

cracked

or

split Replace

tubing

Nozzle set to high pressure

Move nozzle to low pressure position

Siphon

nozzle

blocked

Clean

nozzle

Trigger will not move

Trigger lock engaged

Release trigger lock

Water in crankcase

High humidity

Change oil more frequently

Worn seals

Return to Sealey dealer for seal replacement

Noisy operation

Worn bearings

Return to Sealey dealer for bearing replacement

Air mixed with water

Check inlet line for correct size or restriction

Rough/pulsating operation with

Inlet restriction

Check for incorrectly sized plumbing, air leaks, or

pressure

drop

blockages

Air mixed with water

Check inlet line for correct size or restriction

High crankcase temperature

Wrong grade of oil

Use recommended oil

Oil level too high / low Adjust oil level to recommended

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

W e b

email

Original Language Version

PCM2500.V2 Issue: 2 - 13/10/11

Environmental Protection.

Recycle unwanted materials instead of disposing of them as

waste. All tools, accessories and packaging should be sorted,

taken to a recycle centre and disposed of in a manner which

is compatible with the environment.

WEEE Regulations.

dispose of this product at the end of its working life in compliance

with the eU directive on Waste electrical and electronic equipment.

When the product is no longer required, it must be disposed of in an

environmentally protective way. Contact your local solid waste

authority for recycling information.

NOTe: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of

experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible

for their safety. Children should be supervised to ensure that they do not play with the appliance.

© Jack Sealey limited

Advertising
This manual is related to the following products: