Electromagnetic compatibility – Sealey MW140A User Manual

Page 6

Advertising
background image

11. ELECTROMAGNETIC COMPATIBILITY

Original Language Version

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, suffolk Business Park

,

Bury st. edmunds, suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

MW140A MW160A MW180A MW200A Issue No1 29/01/13

© Jack sealey limited

11.1. THIs eQUIPMeNT Is IN CoNFoRMITY WITH THe eURoPeAN sTANdARd oN THe eleCTRoMAGNeTIC CoMPATIBIlITY

oF ARC WeldING eQUIPMeNT ANd sIMIlAR PRoCesses (e.g. ARC ANd PlAsMA CUTTING)

11.2. Protection against interference. (E.M.C.) The emission limits in this standard may not, however, provide full protection against

interference to radio and television reception when the equipment is used closer than 30m to the receiving antenna. In special cases,

when highly susceptible apparatus is being used in close proximity, additional mitigation measures may have to be employed in order

to reduce the electromagnetic emissions. At the same time there could occur some potential difficulties in having electromagnetic

compatibility in a non-industrial environment (e.g. in residential areas). Therefore it is most important that the equipment is used and

installed according to the following instructions.

11.3. Installation and use. The user is responsible for installing and using the equipment according to these instructions. If electromagnetic

disturbances are detected, then it shall be the responsibility of the user of the equipment to resolve the situation with the technical

assistance of the supplier. In some cases this remedial action may be as simple as earthing the circuit (see Note). In other cases it

could involve constructing an electromagnetic screen, enclosing the welding power source and the work, complete with associated input

filters. In all cases the electromagnetic disturbances shall be reduced to the point where they are no longer troublesome.

Note: The welding/cutting circuit may or may not be earthed for safety reasons. Changing the earthing arrangements should only be

authorised by a person who is competent to assess whether the changes will increase the risk of injury, e.g. by allowing parallel

welding/cutting circuit return paths which may damage the earth circuits of other equipment. Further guidance is given in IeC 974-13 ’Arc

Welding equipment - Installation and Use.’

11.4. Assessment of area. Before installing the equipment the user shall make an assessment of potential electromechanical problems in the

surrounding area. The size of the surrounding area to be considered will depend on the structure of the building and other activities that

are taking place. The surrounding area may extend beyond the boundaries of the premises.

The following shall be taken into account :

a) other supply cables, control cables, signalling and telephone cables, above, below and adjacent to the welding equipment.

b) Radio and television transmitters and receivers.

c) Computer and other control equipment.

d) safety critical equipment, e.g. security monitoring of industrial equipment.

e) The health of people in the vicinity, e.g. persons fitted with a pacemaker or hearing aid.

f) equipment used for calibration or measurement.

g) The immunity of other equipment in the environment. The user shall ensure that other equipment being used in the environment is

compatible. This may require additional protective measures.

h) The time of day that welding and other activities are to be carried out.

11.5. Mains supply. The equipment should be connected to the mains supply according to these instructions. If interference occurs, it may be

necessary to take additional precautions such as filtering of the mains supply. Consideration should also be given to shielding the supply

cable of permanently installed equipment in metallic conduit or equivalent. This shielding should be connected to the power source so

that good electrical contact is maintained between the conduit and the welding power source enclosure.

11.6. Maintenance of the equipment. The equipment should be routinely maintained according to these instructions. All access and service

covers should be closed and properly fastened when the welding equipment is in operation. The welding equipment should not be

modified in any way except for those changes and adjustments covered in these instructions. In particular, the spark gaps of any arc

striking and stabilising devices should be adjusted and maintained according to the instructions.

11.7. Cables. The welding/cutting cables should be kept as short as possible and should be positioned close together, running at or close

to the floor level.

11.8. Equipotential bonding. Bonding of all metallic components in the welding/cutting installation and adjacent to it should be considered.

However, metallic components bonded to the workpiece will increase the risk that the operator could receive a shock by touching these

metallic components and the electrode at the same time. The operator should be insulated from all such bonded metallic components.

11.9. Earthing of the workpiece. Where the workpiece is not bonded to earth for electrical safety, nor connected to earth because of its size

and position, e.g. ship’s hull or building steelwork, a connection bonding the workpiece to earth may reduce emissions in some, but not

all instances. Care should be taken to prevent the earthing of the workpiece increasing the risk of injury to others or damage to other

electrical equipment. Where necessary, the connection of the workpiece to earth should be made by a direct connection to the

workpiece, but in some countries where direct connection is not permitted, the bonding should be achieved by a suitable capacitance,

selected according to national regulations.

11.10. selective screening and shielding of other cables and equipment in the surrounding area may alleviate problems of interference.

screening of the entire welding/cutting installation may be considered for special applications.

Environmental Protection.

Recycle unwanted materials instead of disposing of them as

waste. All tools, accessories and packaging should be sorted,

taken to a recycle centre and disposed of in a manner which

is compatible with the environment.

WEEE Regulations.

dispose of this product at the end of its working life in compliance

with the eU directive on Waste electrical and electronic equipment.

When the product is no longer required, it must be disposed of in an

environmentally protective way. Contact your local solid waste

authority for recycling information.

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to:

www.sealey.co.uk, email: [email protected] or phone:01284 757500.

Advertising