Advanced Microprocessor with Graphics Control Setup

19

Figure 4

Advanced microprocessor with graphics (AG) control menu

Normal

Display

Date and Time

Set Clock

** Optional

Cursor Movement

Use UP/DOWN to move

the cursor. Hit ENTER to

select the menu item.
ESC key moves backward

through menus toward the

Main Menu.

Any Key

except

ON/OFF

ESC key

72°F Unit On
50% Reheat

Dehumidifying
Cooling

* * *Main Menu* * *

View Water

Detect Floor Plan

Setup Water

Detect Floor Plan

Use / to Locate File
Use ENTER to define file

High Temperature
Low Temperature
High Humidity
Low Humidity
Low Suction Comp 1
Low Suction Comp 2
Short Cycle Comp 1
Short Cycle Comp 2
Compressor 1 Overload
Compressor 2 Overload
Main Fan Overload
Loss of Power
Humidifier Problem
High Head Pressure 1
High Head Pressure 2
Change Filters
Loss of Air Flow
Custom Alarm 1
Custom Alarm 2
Custom Alarm 3
Custom Alarm 4

Setup Alarms

Active Alarms

Alarm History Log

View/Set

Alarms

Operating

Status

Date and

Time

Run

Diagnostics

Plot

Graphs

View/Set Control

Setpoints

Setup

System

Analog/Digital

Inputs

View Run

Hours Log

Operating Status

Compressor Cooling %
Heating %
Glycool %**
Chilled Water Valve %**
Humidification %

View/Set Control Setpoints

Temperature Setpoint
Sensitivity Setpoint
Humidity Setpoint
Sensitivity
High Temperature Alarm
Low Temperature Alarm
High Humidity Alarm
Low Humidity Alarm

Chilled Water**
Glycool**
Compressor 1
Compressor 2
Condenser
Reheat 1, 2, 3
Humidifier
Main Fan

View 24 Hour Run

Time History

Compressor 1
Compressor 2
Glycool**
Main Fan
Humidifier
Reheat 1, 2, 3
Chilled Water**
Heat Rejection

View Total Run Hours

Setup Analog Inputs

Analog Input 1 (2,3,4)

Slope
Units
Text
Intercept

Read Digital Inputs

Setup Digital Inputs

(How-to Text)

Analog Input 1
Analog Input 2
Analog Input 3
Analog Input 4

Read Analog Inputs

Analog Sensor #2 Plot

Temperature Plot

Humidity Plot

Analog Sensor #1 Plot

Analog Sensor #3 Plot

Analog Sensor #4 Plot

Modify Plot Scales

Modify Temp Scales
Modify Humidity Scales
Modify Analog Sensor

#1 Scale
#2 Scale
#3 Scale
#4 Scale

Test Control Board

Microcontroller

Show DIP Switches

Dipswitch 1
Dipswitch 2
Dipswitch 3
Dipswitch 4
Dipswitch 5
Dipswitch 6
Dipswitch 7

Test Outputs

Main Fan
Compressor 1
LLSV 1
HGBP/CUV 1
Compressor 2
LLSV 2
HGBP/CUV 2
CWV/CGV
RS Delay
Reheat 1
Reheat 2
RH3/Dehum Damper
HMV
Common Alarm

Air Sail Switch
Custom Alarm 1
Custom Alarm 2
Custom Alarm 3
Custom Alarm 4
Humidifier Problem
Filter Clog Switch
Main Fan Overload
High Head Compressor 2
Compressor 2 Overload
Shutdown Device
Low Pressure Switch 2
Low Pressure Switch 1
Compressor 1 Overload
High Head Compressor 1

Show Inputs

Calibrate Valve Actuator

Set Status Display

Sensor Reading
Setpoints

Select Humidity

Sensing Mode

Relative
Absolute

Select Control Algorithm

Proportional
Intelligent
Tunable PID

Proportional Gain
Derivative Gain
Integral Gain

Calibrate Sensors

Temperature Sensor
Humidity Sensor
Calibrated Reading

Change Passwwords

Setpoint Password
Setup Password

Change Passwords

Setup Operation

Cold Start Delay
Auto Restart Delay
IR Flush Overfill
CW/HW Coil Flush
Display in Degrees (F/C )
Min Chilled Water Temp**

Select Options

Reheat
Humidify
Dehumidify
Humidifier Pan Size
Hot Gas Reheat
Stages of Reheat
Dehumidification Stages

Setup Custom Alarms

Setup Custom Alarm Text
Change Custom Text 1
Change Custom Text 2
Change Custom Text 3
Change Custom Text 4