C10 Remove the filter cartridge from the head by

pulling it out as per illustration.

The filter cartridge can be disposed of

with normal household waste.

Before installing the new filtering car-

tridge, wash the plastic filter body with a

washing up liquid and rinse thoroughly.

C11 Remove the new filter cartridge from the

packaging and fit it by firmly pushing it into the fil-

ter head, making sure it is firmly and securely fit-

ted. Make sure the new filter you are fitting comes

in a sealed bag for hygienic purposes.

C12 Screw the filter head and the filter body to-

gether, making sure it is firmly tightened.

C13 Fit the filter assembly with the back into the

appliance as follows:

1. Insert the filter assembly back into its cradle,

aligning the two male spigots with the female

holes in the cradle. Push firmly until the filter

sits snugly and is flush inside the cradle and

with the cradle top surface.

2. Lock the filter by closing the locking lever un-

til it ‘clicks’ into place

3. Rotate the red rotating lever back into the

LOCK position.

C14 Re-fit the lid, making sure the front is atta-

ched first. If the lid is not fitted correctly the unit

will not switch on.

Fit the lid making sure the front is

pushed in place first and then push the

back end with the screws down to give a snug

fit.

C15 Re-fit the two screws that hold the lid down

using the screwdriver.

The screws should be hand tightened,

do not over tighten.

C16 Insert the plug into the mains socket and

press and hold the dispense button for 10 secon-

ds until you hear a beep as this will reset the filter

timer.

and pulling it up.

C5 To remove the UV lamp firmly pull it up and

out. Do not pull the lamp out at an angle as it may

break or damage the internal parts of the applian-

ce.

The UV lamp must be disposed of cor-

rectly and must not be disposed of with

normal household waste.

C6 Insert the new UV lamp while holding the

white end caps only. Insert the UV lamp as shown

in the illustration and push it all the way down until

it cannot go any further.

Do not use force when removing and in-

serting the UV lamp as you may damage

internal parts. Do not touch the UV lamp glass

surface with your fingers as this will affect the

performance of the UV lamp.

C7 Re-connect the UV lamp connector making

sure the connectors are lined up correctly as they

will only fit together when correctly aligned.

Pay attention not to wet the UV lamp

connector; in case of water drops on UV

lamp connectors, do not reconnect to power

mains before drying completely.

Wear disposable gloves during the ope-

rations of filter removal hereafter descri-

bed to avoid the direct contact with wet parts.

C8 To remove the Filter, do the following:

1. Rotate the red rotating lever so that it is pa-

rallel with the side panel.

2. Insert your finger into the round hole of the

lever, and pull the lever up to the vertical

position.

3. Pull the lever straight up to remove the Filter

assembly (some slight force may be requi-

red).

C9 Unscrew the filter body from the filter head

by turning the base in a anti clockwise direction as

per the illustration.

Be careful as the filter body will contain

water.