Hotpoint Ariston CT NTC IX2 User Manual

Page 15

Advertising
background image

hotpoint.

eu

17

en

Unit of

measure-

ment

Limit value

Italian Legis-

lative Decree

31/01 and

following

amendments.

Pre-

filtration

water 1 l

Post-

filtration

water 1 l

Δ 1l

Pre-

filtration

water

1501 l

Post-

filtration

water

1501 l

Δ 1550 l

Trichloromethane

µg/l

*

22

<0.5

-100%

24

6.4

-73%

Bromodichloromethane

µg/l

*

8.6

<0.5

-100%

9.5

0.5

-95%

Dibromochloromethane

µg/l

*

7.9

<0.5

-100%

6.4

<0.5

-100%

Tribromomethane

µg/l

*

4.7

<0.5

-100%

1.5

<0.5

-100%

Sum of trihalomethanes

µg/l

30

43.2

-/-

-100%

41.4

6.9

-83%

Chlorite

µg/l

700

4000

<90

-100%

370

<90

-100%

-/- = below detectability limit

*= Parameters required by Italian Legislative Decree 31/01, whose maximum limit is expressed as sum

of trihalomethanes

A reduction performance of 100% was considered for parameters below the detectability limit after

filtration

The parameters of Italian Legislative Decree 31/2001 (as amended by WATER MACHINE) are included

in the following list with the relevant performance values guaranteed for a filter's lifespan based on an

average annual use of 1500 litres.

Other parameters of Italian Legislative Decree 31/2001 (as amended) are iron, copper and nitrates.