5.6. INSTALLATION OF TEMPERATURE PROBE

The temperature probe must be connected to the control unit and to

the duct (1) of a kit (see diagram below) and has a length of 2.5 m.

Greater distances require the use of and extension to be provided by

the installer.

PROBE INSTALLATION

• Insert the plastic piece C in D and screw in B without forcing it.

On the threaded part of piece D insert washer E

• The group thus formed A1 must be inserted on the rigid part of

the cable of probe A

• Identify the pass-through hole for insertion of the probe on the

duct (1); on the grille at lower right alongside the fan.

• Insert in the hole the cable of probe A with the block A1 and

secure it on the other side with the nut F

• Insert the other end of the cable of probe A in the control unit

in the indicated position (12-11)

5.7. DOOR OPEN SWITCH

On fireplace stoves of the “Puro” line, MCZ has installed a switch which,
in the case of forced ventilation, must be connected to terminals 9-10

of the control unit, after removing the connection between the 2

terminals provided by the manufacturer. To this end, place an

extension of adequate length, in silicone material resistant to high

temperatures. Make sure the cable does not come into contact with the

hot parts of the fireplace stove.
This switch disables the fans when the door of the fireplace

stove is opened. This is indicated by the flashing of the fan active

indicator light (LED 2 see chap. 5.5).

IMPORTANT!
Mcz shall not be held liable for smoke coming out of

the air outlets if the switch is not properly connected

to the control unit.