LuMIN8 Installation Instructions

10

Sounder Trigger Connection - Serial Mode, ProSYS FreeCom

BUS (Serial) connection to ProSYS FreeCom

BLK

COM

BELL

+

YEL GRN

+

-

HOLD

GRN

YEL

PRO BUS

LuMIN8 Sounder

ProSYS FreeCom

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

ON

SW1

SW2

SW3

SW4

SW5

SW6

SW7

SW8

DIPSWITCH

SCB/SAB

A1

A2

A3

BUS/STD

PRO/ACT

MON/NM

TMF/EXT

Sounder defined

as unit No. 2

BUS

Sounder Trigger Connection - Serial Mode to GT Control Panel,
Parallel Mode

+

-

HOLD

TMPR

TRIG

ACT BUS

LuMIN8 ID 2

GT Control Panel

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

ON

SW1

SW2

SW3

SW4

SW5

SW6

SW7

SW8

DIPSWITCH

SCB/SAB

A1

A2

A3

BUS/STD

PRO/ACT

MON/NM

TMF/EXT

Sounder defined

as unit No. 2

+

-

BELL

BELL

HOLD

SAB

TMP

+

-

HOLD

TMPR

TRIG

ACT BUS

LuMIN8 ID 1

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

ON

SW1

SW2

SW3

SW4

SW5

SW6

SW7

SW8

DIPSWITCH

SCB/SAB

A1

A2

A3

BUS/STD

PRO/ACT

MON/NM

TMF/EXT

2 Lumin8 Sounders connection to GT Panel in

Serial mode using power supply for unit 2

Sounder defined

as unit No. 1

12V PSU

+

-

Note: In Sounder 2 set SW8 to ON
position to get a low current
consumption. T

Commissioning

Before powering the unit, ensure all dipswitches are in the required position. After the wiring has been
completed the system should be powered up. Note that if the unit has a trigger (including tamper) it will
sound for four seconds and then it will cut off (engineer test). The sounder may then only be re-
triggered by clearing the original trigger (or tamper). This four second timer is only available at power
up.

Notes:

1. Sounder cut-off time is 15 minutes unless the supply voltage is less than 13V when triggered the cut-off time is 5

minutes.

2. Strobe will flash at 1.25Hz unless the control panel appears to be running on battery; if so the strobe will flash once

every 5 seconds.