Retrotec Multi-Fan Blower Door User Manual

Page 2

Advertising
background image

Page 2 of 37
©Retrotec Inc. 2015

Copyright © 2013-2015 Retrotec Inc.,

All rights reserved.

This document contains materials protected under International and Federal Copyright Laws. No part of this book
may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying,
recording, or by any information storage and retrieval system without express written permission from Retrotec
Inc.

Retrotec makes no warranties with respect to this documentation and disclaims any implied warranties of
merchantability, quality, or fitness for any particular purpose. The information in this document is subject to
change without notice. Retrotec reserves the right to make revisions to this publication without obligation to
notify any person or entity of any such changes.

FanTestic is a Trademark of Retrotec Inc. Other trademarks or brand names mentioned herein are trademarks or
registered trademarks of their respective owners.

Table of Contents

1.

When do you need more than one fan? ....................................................... 4

1.1

Maximum flow capacity of Retrotec fans ................................................................ 4

1.2

Calculate number of fans needed based on leakage requirement ............................ 5

1.3

Use Retrotec’s ‘Number of Fan Calculator’ spreadsheet .......................................... 6

1.4

Use Retrotec’s ‘Number of Fan Calculator’ spreadsheet, for Enclosure Integrity Tests

7

2.

Large Building Leakage tests ......................................................................... 8

2.1

Total Zone Leakage Test .......................................................................................... 8

2.2

Zone-to-Zone Leakage Test ..................................................................................... 9

2.2.1.

Pressure Neutralization .......................................................................................... 9

2.2.2.

Measure Leakage between floors using pressure neutralization........................... 9

2.2.3.

Measure Leakage between rooms using pressure neutralization ....................... 10

3.

Options for controlling the speed of multiple fans ...................................... 12

3.1

Common set point control .................................................................................... 12

3.1.1.

Without FanTestic software.................................................................................. 12

3.1.2.

With FanTestic software: ...................................................................................... 12

3.2

Individual set point control ................................................................................... 12

3.2.1.

Without FanTestic software: ................................................................................ 12

3.2.2.

With FanTestic software: ...................................................................................... 12

4.

Options to set up test parameters and collect test data ............................. 13

4.1

Manual Data Collection without using FanTestic ................................................... 13

Advertising