Gauge set up to meet energy star standards – Retrotec DU200 DucTester Testing Procedures to meet EnergyStar Standards User Manual

Page 4

Advertising
background image

Page 4 of 4

Gauge set up to meet ENERGY STAR standards


The first time you use the DM-2, press [Auto Zero] to turn it “On,” and press [Time Avg] until it is set to
“8s”.

If the door fan pressure fluctuates more than 2 Pa, press [Time Avg] to reduce the pressure fluctuations. If pressure

fluctuations are still above 2 Pa, use the [Baseline] feature as outlined in QuickGuide-DM2MkII.

Press [Setup] and scroll to “Device Setup” using [

], [].

Press [

], and [] to change the current selection and enable the Devices needed, which are:

“DU200” for the Q32 DucTester and “1000” for the Door Fan. Press [Exit].



Scroll to “Mode Setup” using [

], [].

Press [

], and [] to change the current selection and enable the Modes needed, which are shown below.

Air change is only needed if you are using a Door Fan.