Record

Waveform recorder records input waveforms from CH1 and CH2, with a maximum
record length of 1000 frames. This performance can also be activated by the
Pass/Fail test output, which makes this function especially useful to capture
abnormal signals in long term without keeping an eye watching it. This function
contains four modes: OFF, Record, Play back and Storage. More details about the
function please refer to the following introduction.


1. OFF: It will close all record functions.

2. Record: To record waveform by selected time interval till the last frame.

Press Utility→Record→Mode→Record to go to the following menu.

Figure 2- 101 Table 2- 64 The Record menu (Page 1/2)

Menu

Settings

Comments

Mode

Record
Play back
Storage
OFF

Select record mode
Select play back mode
Select storage mode
Turn off all recorder functions

Source

CH1
CH2
P/F-OUT

Select record source channel

End Frame

<1-1000>

Set number of record frames

Operate

(Run)

(Stop)

Record stopped, press to
Start recording
Recording, press to stop