Select and order the options – RIGOL DP832A User Manual

Page 4

Advertising
background image

Readback

Annual Accuracy

(25℃±5℃)

Voltage

[2]

0.1%+25mV/0.05%+5mV

Current

[2]

0.15%+10mA/0.15%+10mA

Programming

Resolution

Voltage

[2]

1mV/1mV

10mV/10mV

Current

[2]

0.1mA/1mA

1mA/10mA

Transient Response Time

Less than 50μs for output voltage to recover to within 15mV following a change in

output current from full load to half load or vice versa.

Note

[2]

: CH1/CH2.

Single-channel models

Model/Order NO.

DP811A

DP811

Channel Output

Range1: 0 to 20V/0 to 10A

Range2: 0 to 40V/0 to 5A

Max. Total Power

200W

Ripples and

Noise

(20Hz to 20MHz)

Normal

Mode

Voltage

<350μVrms/2mVpp

Normal

Mode

Current

<2mArms

Load Regulation

Rate

Voltage

<0.01%+2mV

Current

<0.01%+250μA

Linear

Regulation Rate

Voltage

<0.01%+2mV

Current

<0.01%+250μA

Programming

Annual Accuracy

(25℃±5℃)

Voltage

0.05%+10mV

Current

0.1%+10mA

Readback

Annual Accuracy

(25℃±5℃)

Voltage

0.05%+10mV

Current

0.1%+10mA

Programming

Resolution

Voltage

1mV

10mV

Current

0.5mA

10mA

Transient Response Time

Less than 50μs for output voltage to recover to within 15mV following a change in

output current from full load to half load or vice versa.

2. Select and order the options

DP832A/DP831A/DP821A/DP811A

For these models, the high-resolution setting, trigger, monitor, analyzer as well as the RS232 and LAN

communication functions are all standard functions. You can select and order the following option

according to your need.

Option

Function Description

Order NO.

USB to GPIB Interface

Converter

You can extend a GPIB interface via the USB HOST interface at the

rear panel of the instrument using this module. Then, connect the

instrument to the PC using a GPIB cable to realize the communication

between the instrument and PC via the GPIB interface.

USB-GPIB

DP832/DP831/DP821/DP811

For these models, the high-resolution setting, trigger, monitor, analyzer as well as the RS232 and LAN

communication functions are all optional functions. You can select and order the following options

according to your need.

Note: To install the high-resolution option, digital I/O option, on-line monitor and analysis option as well as the RS232 and

LAN communication interfaces option, you need to get the corresponding option license. For the acquisition method of the

option license and the installation procedures of the options, refer to the corresponding specific manual (you can download

the manual from

RIGOL official website (

www.rigol.com

)).

Advertising
This manual is related to the following products: